Energy Ceramic

Bricks

Energy Ceramic

Bioclimatic building with the “Energy Ceramic” thermal insulating brick system.

With single-leaf masonry made of “Energy Ceramic” thermal insulating bricks, you bring the principles of bioclimatic design into your new home: lower heating, cooling and lighting needs, a better microclimate, smooth integration of the building into its surroundings and maximum quality of life.

A complete range of thermal insulating bricks is available, in sizes that cover every single-leaf masonry application.

Energy Ceramic brochure (PDF)

Energy Ceramic thermal insulating bricks
Up to 10% additional building area. According to circular YPEN/DAOKA/45724/1558/9.5.2022 of the Greek Ministry of Environment and Energy, “Energy Ceramic” bricks are not counted in the building coefficient, as thermal insulating masonry units with an equivalent thermal conductivity λ’ ≤ 0.30 W/(mK) (design λ’).
⬇ Download the circular (PDF in Greek, 584 KB)

Less energy

Lower heating, cooling and lighting needs, with thermal inertia that stores heat.

+10% building area

Insulating units with λ’ ≤ 0.30 W/mK, not counted in the building coefficient.

Natural material

Clay, water and fire: recyclable, long life cycle, healthy indoor climate.

Products & thermal properties

ProductEnergy Ceramic
20 cm
Energy Ceramic
25 cm
Energy Ceramic
30 cm
Energy Ceramic
25 cm horizontal
General characteristics
Dimensions (cm)22 × 20 × 1922 × 25 × 1922 × 30 × 1930 × 25 × 17
Pieces / m²21 mortar 8 mm
22 adhesive 3 mm
21 mortar 8 mm
22 adhesive 3 mm
21 mortar 8 mm
22 adhesive 3 mm
18 mortar 8 mm
19 adhesive 3 mm
Weight / piece7.1 kg9.1 kg10.3 kg10.7 kg
Compressive strength10 N/mm²
bearing face 22 × 20
10 N/mm²
bearing face 22 × 25
10 N/mm²
bearing face 22 × 30
5 N/mm²
bearing face 25 × 30
Thermal properties (W/mK)
Thermal conductivity of unitλ10,dry,unit (P4)0.1970.2060.1970.226
Thermal conductivity of masonryλ10,dry,masonry – adhesive 3 mm0.1980.2070.2110.237
Thermal conductivity of masonryλ10,dry,masonry – mortar 8 mm0.2140.2230.2330.252
Design thermal conductivityλ10,design,masonry – adhesive 3 mm
4% moisture by volume, per KENAK
0.2460.2570.2620.294
Design thermal conductivityλ10,design,masonry – mortar 8 mm
4% moisture by volume, per KENAK
0.2650.2770.2890.312

Thermal conductivity values in W/mK. Highlighted: design values per KENAK. λ’ ≤ 0.30 W/mK: the bricks are not counted in the building coefficient.

The thermal properties of our products comply with ELOT EN 1745:2012 and ELOT EN 6946:2009, while the calculation method has been validated according to ELOT EN ISO 10211:2009.

EN 1745
EN 6946
EN ISO 10211

The advantages of single-leaf masonry

Thermal inertia – heat capacity

The special hole pattern, combined with high heat capacity, reduces heat losses and increases thermal inertia: the wall becomes an energy “store”. In winter, solar gains are used for many hours; in summer, the coolness of night ventilation is retained.

Thermal insulation

The increased insulating capacity reduces the need for additional insulation, meeting KENAK requirements in the best and most economical way. Thermal properties have been calculated and optimised with modern simulation methods.

Ideal microclimate

Thanks to the porosity of their mass, bricks act as humidity regulators: they release moisture when the air is dry and absorb it when it is humid.

Combined benefits

Better indoor climate, heat storage and thermal insulation, earthquake resistance and increased fire resistance – essential qualities for bioclimatic buildings and total-quality constructions.

Single-leaf masonry, i.e. masonry made of thick bricks with high thermal resistance, has significant advantages over any other form of construction: excellent earthquake and fire resistance, significant sound insulation and remarkable thermal insulation, which, combined with high heat capacity and relatively low cost, make it a unique building element for low-energy buildings. During an earthquake it performs much better than double masonry with a cavity.

Elizabeth Vintzileou, Professor, National Technical University of Athens

KENAK climate zones

A

Heraklion, Chania, Rethymno, Lasithi, Cyclades, Dodecanese, Samos, Messinia, Laconia, Argolida, Zakynthos, Kefalonia & Ithaca, Kythira & Saronic islands, Arcadia (lowlands)

B

Attica (except Kythira & Saronic islands), Corinthia, Ilia, Achaia, Aetolia-Acarnania, Fthiotida, Fokida, Boeotia, Evia, Magnesia, Lesvos, Chios, Corfu, Lefkada, Thesprotia, Preveza, Arta

C

Arcadia (mountainous), Evrytania, Ioannina, Larissa, Karditsa, Trikala, Pieria, Imathia, Pella, Thessaloniki, Kilkis, Chalkidiki, Serres (except NE part), Kavala, Xanthi, Rhodope, Evros

D

Grevena, Kozani, Kastoria, Florina, Serres (NE part), Drama

In each prefecture, areas above 500 m altitude belong to the next colder zone. Zone D includes all areas regardless of altitude.

KENAK climate zones map

Build with Panagiotopoulos bricks

Available at building materials stores. For technical information and help choosing the right masonry, our team is at your disposal.

Are you a building materials dealer or a construction company? Contact us about working together.